General Information - Gen-Two+
The GEN-Two + unit utilizes a 9-Volt DC Independent (3/6 months)
Operating System. This controller will work with MOST traps regardless
of make, model, voltage, or release type. When the unit reads "Traps
OFF" on the display, the release buttons are disabled from
traps, but they will still work to change the various menus.

Turning Unit On/Off
To turn on your Gen-Two + unit, press the button in the lower right
corner once.
This unit turns On/Off with the same button.
Menu Functions
- To enter the menu mode, press and hold the menu switch button
located on the lower left of your unit.
- Turn off menu by releasing the menu button.
- To change between Menus or set Delay Timers, you must be in
the Menu Mode.
Trap Buttons
- Trap 1 button controls delay timer for Trap 1.
- Trap 2 button controls delay timer for Trap 2.
- The Pairs button will change the Menu Modes.
Trap Release
- There are no delays to set when in the Trap Release Mode.
- When you press the Trap 1 button - trap 1 fires immediately.
- When you press the Trap 2 button - trap 2 fires immediately.
- When you press the Pair Button both traps fire immediately.
Report Pair
- There are two delay displays in the Report Pair Mode.
- The left delay display is used to set the delay between the
time the initial button is pushed and when the first trap fires.
- The right delay display is used to set the delay time between
the firing of trap 1 and the firing of trap 2 for a report pair.
- When you press the Trap 1 button - trap 1 will fire after the
elapsed time set on the left delay display.
- When you press the Trap 2 button - trap 2 fires after the elapsed
time set on the left delay display.
- When you press the Pair Button, trap 1 fires after the elapsed
time set on the left delay display and trap 2 fires after the
elapsed time set on the right delay display.
True Pair
- There is one delay display for the True Pair Mode.
- The left delay display is used to set the delay between the
time the initial button is pushed and when the first trap fires.
- When you press the Trap 1 button - trap 1 fires after the elapsed
time set on the left delay display.
- When you press the Trap 2 button - trap 2 fires after the elapsed
time set on the left delay display.
- When you press the Pair Button - trap 1 and trap 2 fire simultaneously
after the elapsed time set on the left delay display.
Following Pair - Trap 1
There are two delay times to set in the Following Pair 1 Mode.
- The left delay display is used to set the delay between the
time the initial button is pushed and when the first bird fires
from trap 1.
- The right delay display is used to set the delay between the
firing of the first bird from trap 1 and the firing of the second
bird from trap 1.
- When you press the Trap 1 button - trap 1 fires after the elapsed
time set on the left delay display.
- When you press the Pair Button - trap 1 fires the first bird
after the elapsed time set on the left delay display and then
fires the second bird after the elapsed time set on the right
delay display.
Following Pair - Trap 2
There are two delay times to set in the Following Pair 2 Mode.
- The left delay display is used to set the delay between the
time the initial button is pushed and when the first bird fires
from trap 2.
- The right delay display is used to set the delay between the
firing of the first bird from trap 2 and the firing of the second
bird from trap 2.
- When you press the Trap 2 button - trap 2 fires after the elapsed
time set on the left delay display.
- When you press the Pair Button - trap 2 fires the first bird
after the elapsed time set on the left delay display and then
fires the second bird after the elapsed time set on the right
delay display.
Reset Pack Use
Resetting Daily Totals:
- Plug the Gen-Two + Unit into a Gen-Two + Reset Pack
- Press the Menu button and hold on.
- Press the Pair button and hold ON for 15 seconds. A Daily Reset
screen will be displayed.
- To clear this screen, release both the Pair and Menu buttons.
Obtaining Grand Totals:
- Press the Menu button and hold on.
- Press the Trap 1 button and hold ON for 15 seconds. A Grand
Total view screen will be displayed.
- To clear the unit release both the Menu and Trap 1 buttons and
switch the unit off for 3 to 5 seconds. Turn unit back on to resume
normal operation.
Changing Programs from Timed Trap Release to Trap Release:
- Plug Gen-Two + unit into the Reset Pack
- Press the Menu button and hold on.
- Set Menu to Timed Trap Release
- Press and hold the Trap 2 button ON for 15 seconds. This will
change the Gen-Two + unit from Program #1 (Timed) to Program #2
(Trap Release Only Mode ).
- To clear the Program Change Screen, turn the Gen-Two + unit
off for 3 to 5 seconds. Turning your controller back on with the
new Program installed.
To reverse this Mode:
- Hold Menu button down displaying a Reset Screen.
- At this screen all unit clearing function can be performed (Grand
Totals, Daily Totals, plus changing back to Timed Trap Release
Mode.
Additional Assistance
Custom Plastics Design
2910 Hance Road
Binghamton, NY 13903
dgray@southerntierplastics.com
607.669.4610 - phone
607.723.2601 - phone
607.772.9881 - fax
|
 |